Parkside PLEM 50 A1 Operating Instructions Manual

Kategoria
Measuring & layout tools
Tyyppi
Operating Instructions Manual
LASER DISTANCE MEASURER PLEM 50 A1
LASER DISTANCE MEASURER
Operating instructions
LASERAVSTÅNDSMÄTARE
Bruksanvisning
LASER-ETÄISYYSMITTARI
Käyttöohje
IAN 100719
LASERAFSTANDSMETER
Gebruiksaanwijzing
LASER-ENTFERNUNGSMESS-
GERÄT
Bedienungsanleitung
CV_100719_PLEM50A1_LB3.indd 2 28.08.14 10:39
GB / IE Operating instructions Page 1
FI Käyttöohje Sivu 23
SE Bruksanvisning Sidan 45
NL / BE Gebruiksaanwijzing Pagina 67
DE / AT / CH Bedienungsanleitung Seite 89
Before reading, unfold the page containing the illustrations and familiarise
yourself with all functions of the device.
Käännä ennen lukemista kuvallinen sivu esiin ja tutustu seuraavaksi laitteen
kaikkiin toimintoihin.
Vik ut bildsidan och ha den till hands när du läser igenom anvisningarna och
gör dig bekant med apparatens / maskinens funktioner.
Vouw vóór het lezen de pagina met de afbeeldingen open en maak u
vertrouwd met alle functies van het apparaat.
Klappen Sie vor dem Lesen die Seite mit den Abbildungen aus und machen
Sie sich anschließend mit allen Funktionen des Gerätes vertraut.
CV_100719_PLEM50A1_LB3.indd 3 28.08.14 10:39
A
CV_100719_PLEM50A1_LB3.indd 4 28.08.14 10:39
1
PLEM 50 A1
GB
IE
Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Package contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Safety guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Risk of injury if batteries are improperly handled . . . . . . . . . . . . . . .7
Initial operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Attaching the wrist strap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Inserting/replacing the batteries . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Acoustic signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Switching on and off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Display illumination . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Handling and operation . . . . . . . . . . . . . . . . . . . . . . . . 10
Selecting the length unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Selection of the reference plane . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Angle stop . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Measuring lengths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Measurement value functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Measured value memory/Calling up a saved measurement . . . . .16
Clear button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Belt pouch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Maintenance and Cleaning . . . . . . . . . . . . . . . . . . . . . . 19
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Disposal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Disposal of the device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Disposing of the batteries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Importer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
IB_100719_PLEM50A1_LB3.indb 1 28.08.14 10:52
GB
IE
2
PLEM 50 A1
LASER DISTANCE MEASURER PLEM 50 A1
Introduction
Congratulations on the purchase of your new device.
You have selected a high-quality product. The operating
instructions are part of this product. They contain important
information on safety, usage and disposal. Before using the product,
familiarise yourself with all handling and safety guidelines. Use the
product only as described and for the range of applications specifi ed.
Please also pass these operating instructions on to any future owner(s).
Intended use
The PLEM 50 A1 laser distance measurer (hereinafter device) is suitable
for:
measuring distances, lengths, heights, gaps and for calculating
areas and volumes in indoor spaces.
Any other usage of or modifi cation to the device is deemed to be
improper usage and carries the risk of serious personal injury.
The manufacturer accepts no responsibility for damage(s) arising
out of usage contrary to the instructions specifi ed below.
The device is not meant for commercial use.
Components
Display
ON
button
button
button
C
OFF
button
Angle stop (fold-out)
UNIT
button
button
IB_100719_PLEM50A1_LB3.indb 2 28.08.14 10:52
3
PLEM 50 A1
GB
IE
FUNC
button
Battery compartment cover
Receiver lens
Laser beam output opening
Belt pouch
Wrist strap
Figure A (display)
Laser on
Laser reception strength
Measurement value functions
Data storage
Battery charge level display
Measurement value 3
Measurement value 2
Length unit
Single measurement value (result)
Min. measurement value
Hardware error icon
Max. measurement value
Reference plane
Package contents
The device is supplied with the following components as standard:
Laser distance measurer PLEM 50 A1
2 x 1.5 V LR03 batteries (AAA)
Belt pouch
Wrist strap
Operating instructions
IB_100719_PLEM50A1_LB3.indb 3 28.08.14 10:52
GB
IE
4
PLEM 50 A1
WARNING!
Packaging material must not be used as a plaything.
Risk of suff ocation.
NOTE
Check the consignment for completeness and for signs of
visible damage.
If the consignment is incomplete or damaged due to defective
packaging or carriage, contact the Service hotline
(see the chapter Service).
Technical data
Measurement range: 0.05–50 m
A)
Measuring accuracy (typical): ± 2.0 mm
B)
Smallest display unit: 1 mm
Operating temperature: 0°–40°C
Relative humidity max.: ≤ 75%
Laser category: 2
Wavelength (λ): 650 nm
Maximum power P max: < 1 mW
Batteries: 2 x 1.5 V LR03 (AAA)
Weight: 88 g
Dimensions: 11.3 x 4.9 x 2.6 cm
A) The range improves the better the laser light is returned from the
surface of the target (dispersing, not refl ecting) and the brighter the
laser is compared to the ambient light (interior rooms, twilight).
IB_100719_PLEM50A1_LB3.indb 4 28.08.14 10:53
5
PLEM 50 A1
GB
IE
B) In unfavourable conditions such as strong sunlight or poorly
refl ective surfaces, the maximum deviation is ± 10 mm at 50 m. In
favourable conditions, a deviation infl uence of ± 0.05 mm/m must
be taken into account.
Safety guidelines
Do not use the device in locations where there is a risk of fi re or
explosion, e.g. in the vicinity of infl ammable liquids or gases.
This device may be used by children of the age of 8 years or
more and by persons with reduced physical, sensory or mental
capabilities or lack of experience and/or knowledge if they are
being supervised or have been instructed with regard to the safe
use of the device and have understood the potential risks. Children
must not use the device as a plaything. Cleaning and user mainte-
nance should not be performed by children unless they are under
supervision.
Do not leave the device unattended when switched on, and
switch off the device directly after use. Other people could be
blinded by the laser beam.
Protect the device from wetness or direct sunlight.
Do not expose the device to any extremes of temperature or
temperature fl uctuations. For example, do not leave it in a car for
extended periods. After exposure to large temperature fl uctuations,
allow the device to acclimatise before using it again. The precision
of the device can be adversely aff ected by extreme temperatures
or temperature fl uctuations.
Avoid hefty knocks or dropping the measuring tool.
IB_100719_PLEM50A1_LB3.indb 5 28.08.14 10:53
GB
IE
6
PLEM 50 A1
WARNING! Protect yourself from laser radiation!
Never look directly into the laser beam or into the opening from
which it emerges.
WARNING!
Looking at a laser beam through optical instruments
(e.g. magnifying glasses etc.) can cause eye injuries.
Attention! If operating and adjustment equipment is used or
procedures other than those specifi ed here are carried out,
this may result in hazardous radiation exposure.
Never aim the laser beam at refl ective surfaces, people or animals.
Even brief visual contact with a laser beam can result in eye injuries.
IB_100719_PLEM50A1_LB3.indb 6 28.08.14 10:53
7
PLEM 50 A1
GB
IE
Risk of injury if batteries are improperly handled
Keep batteries out of the reach of children. Children might put
batteries into their mouth and swallow them. If a battery has been
swallowed, seek medical assistance immediately.
Do not throw batteries into a fi re. Never subject batteries to high
temperatures.
Risk of explosion! Do not charge batteries unless they are explicitly
labelled as "rechargeable".
Do not open the batteries or short-circuit them.
Do not mix diff erent types of batteries.
Due to increased risk of leakage, empty batteries should be re-
moved. The batteries should also be removed from the device if it
is not being used for long periods.
Battery acid leaking from a battery can cause skin irritation.
In event of contact with the skin, rinse with copious amounts of
water. If the liquid comes into contact with your eyes, rinse thor-
oughly with water, do not rub and immediately consult a doctor.
The chapter entitled Inserting/replacing the batteries describes
how to correctly insert and remove batteries.
IB_100719_PLEM50A1_LB3.indb 7 28.08.14 10:53
GB
IE
8
PLEM 50 A1
Initial operation
Attaching the wrist strap
Attach the wrist strap to the hole provided as shown in Figure 1.
F
Fig. 1
Inserting/replacing the batteries
Open the battery compartment cover .
Insert the batteries. Ensure correct polarity as shown on the
diagram inside the battery compartment.
When the low battery icon
appears in the display, you can still
make measurements.
As soon as the battery icon starts fl ashing, however, you must
replace the batteries. Measurements are no longer possible.
Always replace all batteries at the same time. Always use batteries
from the same manufacturer and of the same type.
NOTE
If you do not intend to use the device for a long time, remove
the batteries. During extended periods of storage, the batteries
can corrode and discharge themselves.
IB_100719_PLEM50A1_LB3.indb 8 28.08.14 10:53
9
PLEM 50 A1
GB
IE
Acoustic signal
Each press of a button and every error-free function that is carried
out is confi rmed by a short beep.
A longer beep is only heard in the event of a fault and when switching off .
Switching on and off
To switch the device on, press the ON
ON
button .
When the device is switched on, the laser beam is not yet
activated.
To switch the device off , press and hold the OFF
C
OFF
button .
If no button is pressed for about 3 minutes, the device turns off auto-
matically to save the batteries.
If measured values have been saved, they are retained in the case of
automatic shut-off .
Display illumination
To improve readability, the display is equipped with a backlight.
By pressing the
UNIT
button , the display backlight can be switched
on and off .
IB_100719_PLEM50A1_LB3.indb 9 28.08.14 10:53
GB
IE
10
PLEM 50 A1
Handling and operation
Selecting the length unit
The length unit used after switch-on is the last-used unit.
Press and hold the button
UNIT
to select another unit.
You can set the following length units in this order:
Length Area Volumes
0.000 m 0.000 m
2
0.000 m
3
0.000 ft 0.000 ft
2
0.00 ft
3
0' 0" 1/16 in 0.00 ft
2
0.00 ft
3
0' 0" 1/16 0.00 ft
2
0.00 ft
3
Selection of the reference plane
The lower reference plane (base) or the angle stop or the
upper reference plane
(cover side) of the device can be used as
the contact surface for a measurement.
The reference plane is to be set before measurement otherwise the
measurement result diff ers from the actual value.
The reference plane
(base) is set when the device is switched on.
You can change the reference plane by pressing the button
briefl y.
The selected reference plane
is shown on the display .
IB_100719_PLEM50A1_LB3.indb 10 28.08.14 10:53
11
PLEM 50 A1
GB
IE
Angle stop
Use the angle stop if you are measuring from corners (room
diagonal) or diffi cult-to-reach places.
Fold out the angle stop
as shown in Figure 2.
UNIT
C
OFF
Fig. 2
Measuring lengths
Single measurements
Place or hold the reference plane of the device on or against
the desired base surface from which you want to determine
a distance.
Briefl y press the
ON
button
to activate the laser.
Once the laser is switched on, this is indicated on the display
by the
icon .
Now aim the laser at the target point.
Briefl y pressing the
ON
button again will cause the meas-
urement to be taken.
If the measurement is successful, the measurement result is
shown on the display .
The previous readings and are pushed upwards.
IB_100719_PLEM50A1_LB3.indb 11 28.08.14 10:53
GB
IE
12
PLEM 50 A1
Continuous measurement
Continuous measurement involves taking series of measurements
from which the maximum (
) and minimum values ( )
are displayed. To do this, move the device along a base surface
or an edge from which you want to the measure the distances. You
can, for example, measure how parallel two opposite walls are or
measure the maximum values while using a function.
Start the continuous measurement by pressing the
ON
button
for more than one second.
Each measured value is shown on the display .
Stop the measurement by pressing the
ON
button .
The display now shows the maximum value ( ) and the
minimum value ( )
of the measurement series and the last
measured value .
Measurement value functions
To make it easier to process measurement results, the device off ers
a number of integrated functions.
By pressing the
FUNC
button repeatedly, you can activate the
following functions one after the other:
area, volume, simple Pythagoras, double Pythagoras.
The desired function must be selected before the measurement.
After taking a measurement in the selected function, the last selected
function is reactivated.
Area
Press the
FUNC
button once. The icon appears on the
display .
Now measure the length and width of the area to be meas-
ured by pressing the
ON
button (see also Chapter Single
measurements).
IB_100719_PLEM50A1_LB3.indb 12 28.08.14 10:53
13
PLEM 50 A1
GB
IE
The corresponding line of the icon fl ashes for the indi-
vidual measurement values.
Directly after the second measurement, the calculated area is shown
on the display
and the icon stops fl ashing. The individual
values
, and the results are shown on the display
.
Volumes
Press the
FUNC
button twice. The icon appears on the
display .
Now measure the length, width and height of the volume to
be measured by pressing the
ON
button (see also Chapter
Single measurements). The corresponding line of the
icon
ashes for the individual measurement values.
Directly after the third measurement, the calculated volume is shown
on the display
and the icon stops fl ashing.
Simple Pythagoras
Pythagoras' Theorem describes the dependence of the lengths of the
sides in a right-angled triangle as follows: a
2
+ b
2
= c
2
, where a and
b are the legs and c the hypotenuse of the triangle.
Using the "simple Pythagoras" function, it is possible to calculate the
length of one of the legs. This feature is particularly useful for poorly
accessible measurement points.
Press the
FUNC
button three times. The icon appears on
the display .
Now measure the hypotenuse (largest distance) and one of the
legs (shortest distance to the measurement surface) by pressing
the
ON
button (see also Chapter Single measurements).
The corresponding line of the icon fl ashes for the individual
measurement values.
IB_100719_PLEM50A1_LB3.indb 13 28.08.14 10:53
GB
IE
14
PLEM 50 A1
Directly after the second measurement, the calculated length is
shown on the display
and the icon stops fl ashing.
The individual values , and the results are shown on the
display
.
Please note that angular error (no right angles) will lead to incorrect
results. Ensure that the measured distances lie on a plane (align-
ment).
To ensure the greatest possible accuracy, you can the calculate
the distance of the leg (shortest distance) by means of continuous
measurement. The minimum determined value is automatically
used for the Pythagoras calculation.
The measurement can also be greater than 50 m in length, but
will be shown as a two-digit number.
Double Pythagoras
In this function, Pythagoras' Theorem is applied to two right triangles
that have a common leg.
This makes it possible to calculate the length of the base side of any
triangle. This function calculates the distance between two arbitrary
points and is especially useful for inaccessible measurement points.
Press the
FUNC
button four times. The icon appears on
the display .
Now measure the left hypotenuse (largest distance to the left)
and then one leg (shortest distance to the measurement sur-
face) and fi nally the right hypotenuse (largest distance to the
right) by pressing the
ON
button (see also Chapter Single
measurements).
The corresponding line of the
icon fl ashes for the individual
measurement values.
Directly after the third measurement, the calculated length is shown
on the display
and the icon stops fl ashing.
IB_100719_PLEM50A1_LB3.indb 14 28.08.14 10:53
15
PLEM 50 A1
GB
IE
The individual values , and the results are shown on the
display
.
Please note that angular error (no right angles) will lead to incorrect
results. Ensure that the measured distances lie on a plane (align-
ment).
To ensure the greatest possible accuracy, you can calculate the
distance of the leg (shortest distance) by means of continuous
measurement. The minimum determined value is automatically
used for the Pythagoras calculation.
The measurement can also be greater than 50 m in length, but
will be shown as a two-digit number.
Addition (Plus)
To add two individual values, take a measurement (length, area,
volume) so that the display
is showing a value.
Then press the button
to start the Addition (Plus) function.
The reading now appears on the display , the reading
shows "+
- - - - - -
".
Now take a second measurement (length, area, volume).
The reading is shown on the display
as "+ nnnn".
Directly after the second measurement, the individual values ,
and the result are shown on the display
.
The addition can be carried out with all units (length, area, volume).
You can also include the measurement results of functions (area,
volume, Pythagoras) in the addition.
Only values in the same units can be added. The fi rst measured
value sets the unit to be used.
If the result of an addition is saved in the measured value memory,
the individual values of the sum are also saved.
IB_100719_PLEM50A1_LB3.indb 15 28.08.14 10:53
GB
IE
16
PLEM 50 A1
Subtraction (Minus)
The subtraction of measurements is carried out in the same way as
the addition.
Press the
button to start the subtraction.
The
reading now appears on the display , the reading
shows "
- - - - - -
" and subtracts the individual values of the
measurement from each other. The result can also be a nega-
tive number.
Measured value memory/Calling up a saved
measurement
All measured and calculated values can be stored in the memory.
The values are saved with their unit (length, area or volume). Calcu-
lated values are stored together with the respective individual values.
There are a total of 50 memory locations available. As soon as
all 50 memory locations are occupied, the oldest measurement is
deleted. The new measurement result is then stored on location 50.
Saving a measurement
The last 50 measurement results are automatically stored in the
memory.
Calling up measurement values from the cache
The cache allows quick access to a single memory value. If a value
is used multiple times, the cache is the ideal solution.
Press the
or
buttons to display the values stored in
the cache. The icon appears on the display
along with
the number of the memory location.
By pressing the
or
buttons you can navigate through
the memory locations 1 to 50. The
icon shows the active
memory location.
IB_100719_PLEM50A1_LB3.indb 16 28.08.14 10:53
17
PLEM 50 A1
GB
IE
Clear button
By briefl y pressing the
C
OFF
button you can reset the most
recent action.
Repeatedly pressing the
C
OFF
button will delete the content of
the display in the following order:
.
Belt pouch
Use the supplied belt pouch to protect the device when not in use.
Faults
If a measurement or a result is faulty, this is indicated by "Er nnn"
in the display and a long beep. The possible causes for this are:
Faults Possible cause Rectifi cation
101 Batteries are weak Replace the batteries
104 Calculation error Repeat the process
152
Operating tempera-
ture too high
Please note the correct operating
temperature
153
Operating tempera-
ture too low
154
Measurement out-
side the measure-
ment range
Keep within the maximum measur-
ing range of the device
155
Received signal too
weak
Avoid non-refl ective or poorly
refl ecting surfaces
Find a measurement point that is
more refl ective
IB_100719_PLEM50A1_LB3.indb 17 28.08.14 10:53
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114

Parkside PLEM 50 A1 Operating Instructions Manual

Kategoria
Measuring & layout tools
Tyyppi
Operating Instructions Manual

muilla kielillä