Invacare Matrx PB Elite PBE Ohjekirja

Tyyppi
Ohjekirja

Tämä ohje sopii myös

Part No 1176089 1 Invacare® Matrx® PB Elite
Invacare® Matrx® PB Elite
Model Numbers PBE, PBE-FB and EDB
1 General
1.1 Symbols
Signal words are used in this manual and apply to hazards or unsafe practices which could result in
personal injury or property damage. See the information below for definitions of the signal words.
1.2 Overview
Important Information
The best way to avoid problems related to pressure sores is to understand their causes and your role in
a skin management program.
Your therapist and physician should be consulted if you have questions regarding individual limitations
and needs.
All cushions should be selected carefully. Working with your therapist and physician is the best way to
assure that a cushion choice matches your individual needs.
As the needs of the individual become more complex, cushion evaluation becomes more important.
WARNING
Warning indicates a potentially hazardous situation which, if not avoided, could result in death or
serious injury.
CAUTION
Caution indicates a potentially hazardous situation which, if not avoided, may result in property
damage or minor injury or both.
Gives useful tips, recommendations and information for efficient, trouble-free use.
User Manual
DEALER: This manual MUST be given to the user of the product.
USER:
BEFORE using this product, read this manual and save for
future reference.
FR Manuel d’utilisation................................................................... page 13
DE Gebrauchsanweisung ............................................................... page 28
ES Manual del usuario.................................................................... page 42
PT Manual de utilização................................................................. page 56
IT Manuale d’uso............................................................................ page 70
DA Brugsanvisning ........................................................................... page 85
SV Bruksanvisning........................................................................... page 99
FI Käyttöopas............................................................................... page 113
NL Gebruikershandleiding........................................................... page 127
EE Kasutusjuhend ......................................................................... page 141
LT Naudotojo vadovas ................................................................ page 153
CS Návod k použití....................................................................... page 165
Invacare® Matrx® PB Elite 2 Part No 1176089
Invacare Matrx Elite
The Invacare Matrx Elite back is contoured to provide precise orientation within the wheelchair for
optimal postural support. The foam is oversized to provide extra comfort and protection.
The Invacare Matrx Elite back includes a movable foam lumbar pad that can be installed/inserted behind
the existing foam cushion to provide additional positioning capability. Refer to Lumbar Support (Optional)
on page 11 for instructions on how to insert and adjust your lumbar support.
Outer Cover
The outer cover is made of a mesh material that is moisture resistant and breathable. Regular cleaning
and inspection of the outer cover is recommended. Refer to Care and Maintenance on page 11.
2 Safety
2.1 Transporting the Client Within a Wheelchair Fitted with a Matrx Back in a
Motor Vehicle
The following guidelines should be made available to all parties who are responsible for the transportation
of the client, such as schools and transport providers.
Wherever practicable the client should be transferred out of the wheelchair into a vehicle seat and use
a lap and diagonal seat belt or an appropriate child safety seat.
The Matrx back has been dynamically tested and meets the requirements of ISO 16840-4 and Section 20,
ANSI/RESNA WC/Volume 4 “Wheelchair Seating Systems for Use in Motor Vehicles”. A Surrogate
Wheelchair Base (SWCB) and a Hybrid III Midsize-Adult Male Anthropomorphic Test Device were used
in a forward facing frontal impact test. The SWCB was secured by a four-point, strap type wheelchair tie-
down and the occupant restraint was a vehicle anchored lap and diagonal occupant restraint system.
Matrx backs should only be used in conjunction with wheelchairs that comply with the performance
requirements of ANSI WC19 or ISO 7176-19.
Before Entering the Vehicle Check the Following:
Matrx Back - must be securely fastened into the wheelchair as described in the user manual.
Posture Belts and Harnesses - should remain fitted during transportation, although they are designed to
provide postural support only, they are not intended for safety during transportation.
Head Support - must be securely fitted and correctly adjusted close to the rear of the client’s head during
transportation, in order to reduce the risk of whiplash injuries.
The Wheelchair Tie-down and Occupant Restraint System (WTORS)
Wheelchair Tie-down - The wheelchair must be securely tied down within the vehicle, in a forward facing
position, in accordance with the wheelchair and tiedown manufacturers instructions.
Occupant Restraint - A suitable occupant restraint system must also be fitted in accordance with the
manufacturer’s instructions. A minimum is a lap and diagonal belt (lap belts on their own are not suitable).
Restraints that loop over the shoulder and anchor to the vehicle floor should be avoided where possible,
as they can cause a heavy downward load through the client during an impact, the preferred type anchor
above and behind the shoulder as with a car seat belt. The lap section of the belt should fit snugly over
the pelvis of the client and should not be able to ride up to the abdominal area. The upper torso section
of belt should be in contact with the client’s chest and fit over the shoulder(s), while not cutting into the
neck or slipping off the shoulder(s).
2.2 Intended Use
The Invacare Matrx Elite back is designed to provide precise orientation within the wheelchair for optimal
postural support.
Check ALL parts for shipping damage. If shipping damage is noted, DO NOT use. Contact
carrier/dealer for further instruction.
If the wheelchair and Matrx back are to be transported unoccupied, the wheelchair should be tied
down with suitable equipment according to the manufacturer’s instructions. If the equipment is to
be dismantled for transportation, ensure that all parts are secured safely within the vehicle.
Part No 1176089 3 Invacare® Matrx® PB Elite
2.3 General Warnings
WARNING
DO NOT USE THIS PRODUCT OR ANY AVAILABLE OPTIONAL EQUIPMENT WITHOUT
FIRST COMPLETELY READING AND UNDERSTANDING THESE INSTRUCTIONS AND
ANY ADDITIONAL INSTRUCTIONAL MATERIAL SUCH AS OWNER’S MANUALS, SERVICE
MANUALS OR INSTRUCTION SHEETS SUPPLIED WITH THIS PRODUCT OR OPTIONAL
EQUIPMENT. IF YOU ARE UNABLE TO UNDERSTAND THE WARNINGS, CAUTIONS OR
INSTRUCTIONS, CONTACT A HEALTHCARE PROFESSIONAL, DEALER OR TECHNICAL
PERSONNEL BEFORE ATTEMPTING TO USE THIS EQUIPMENT - OTHERWISE, INJURY OR
DAMAGE MAY OCCUR.
ACCESSORIES WARNING
Invacare products are specifically designed and manufactured for use in conjunction with Invacare
accessories. Accessories designed by other manufacturers have not been tested by Invacare and
are not recommended for use with Invacare products.
INSTALLATION WARNING
The procedures in this manual should be performed by a qualified technician.
After any adjustments, repair or service and before use, make sure that all attaching component
parts are secure.
DO NOT install the Invacare Matrx Elite assembly onto back canes with an outside diameter
greater than 1-inch (25 mm) or less than 3/4-inch (19 mm). Otherwise, injury or damage may
occur.
The mounting position of the Invacare Matrx Elite is directly related to the chair's stability. When
the Invacare Matrx Elite is added to a TILT and/or RECLINING chair, it may cause a decrease in
the chair's stability. It may be necessary to reposition the FRONT CASTERS, REAR WHEELS,
BACK ANGLE, TILT-IN-SPACE, RECLINE POSITION and/or SEAT DEPTH before use. Use
extreme caution when using a new seating position.
When a Matrx Elite is added to a TILT and/or RECLINING chair, a RIGIDIZER BAR or
CROSSBAR must be present to stabilize the back canes.
Ensure the Invacare Matrx Elite is properly secured to the wheelchair before using. Otherwise
injury or damage may occur.
WARNING
Skin condition should be checked very frequently after the installation of any new seating system.
Your therapist and physician should be consulted if you have any questions regarding individual
limitations and needs.
Working with your therapist, physician, and equipment supplier is the best way to assure that a
seating choice matches your individual needs.
As the needs of the individual become more complex, the seating evaluation becomes more
important.
Invacare® Matrx® PB Elite 4 Part No 1176089
2.4 Weight Limitation and Model Numbers
Refer to the chart for the weight limitation and stock model numbers.
PBE = Matrx Elite Back, PBE-FB = Matrx Elite Full Back, EDB = Matrx Elite Deep Back
Grey = size not available
WIDTH HEIGHT CONTOUR
DEPTH
WEIGHT
LIMIT
25 CM 30 CM 36 CM 41 CM 46 CM 51 CM
30 cm PBE3126-NH
1545083
PBE3131-NH
1545084
PBE3136-NH
1545085
PBE3141-NH
1545086
PBE3146-NH
1545087
8 cm
136 kg
33 cm PBE3326-NH
1545088
PBE3331-NH
1545089
PBE3336-NH
1545090
PBE3341-NH
1545091
PBE3346-NH
1545092 8 cm
36 cm PBE3626-NH
1545093
PBE3631-NH
1545094
PBE3636-NH
1545095
PBE3641-NH
1545096
PBE3646-NH
1545097
PBE3651-NH
1545098 8 cm
EDB3631-NH
1543504
EDB3641-NH
1543505
EDB3646-NH
1543506
EDB3651-NH
1543507 15 cm
38 cm PBE3826-NH
1545099
PBE3831-NH
1532092
PBE3841-NH
1532093
PBE3846-NH
1545100
PBE3851-NH
1532094 8 cm
EDB3831-NH
1543508
EDB3841-NH
1543509
EDB3846-NH
1543510
EDB3851-NH
1543511 15 cm
41 cm PBE4126-NH
1545101
PBE4131-NH
1515719
PBE4141-NH
1515720
PBE4146-NH
1545102
PBE4151-NH
1517754 8 cm
EDB4131-NH
1543512
EDB4141-NH
1543513
EDB4146-NH
1543514
EDB4151-NH
1543515 15 cm
PBE4151-FB-NH
1545103 8 cm
43 cm PBE4326-NH
1545104
PBE4331-NH
1515721
PBE4341-NH
1515722
PBE4346-NH
1545105
PBE4351-NH
1517755 8 cm
EDB4331-NH
1543516
EDB4341-NH
1543517
EDB4346-NH
1543518
EDB4351-NH
1543519 15 cm
PBE4351-FB-NH
1545106 8 cm
46 cm PBE4626-NH
1545107
PBE4631-NH
1515723
PBE4641-NH
1515724
PBE4646-NH
1545108
PBE4651-NH
1517756 8 cm
EDB4631-NH
1543520
EDB4641-NH
1543521
EDB4646-NH
1543522
EDB4651-NH
1543523 15 cm
PBE4651-FB-NH
1545109 8 cm
48 cm PBE4826-NH
1545110
PBE4831-NH
1515725
PBE4841-NH
1515726
PBE4846-NH
1545111
PBE4851-NH
1517757 8 cm
EDB4831-NH
1543524
EDB4841-NH
1543525
EDB4846-NH
1543526
EDB4851-NH
1543987 15 cm
PBE4851-FB-NH
1545112 8 cm
51 cm PBE5126-NH
1545113
PBE5131-NH
1532095
PBE5141-NH
1532096
PBE5146-NH
1545114
PBE5151-NH
1532097 8 cm
EDB5131-NH
1543988
EDB5141-NH
1543989
EDB5146-NH
1543990
EDB5151-NH
1543991 15 cm
PBE5151-FB-NH
1545115 8 cm
Part No 1176089 5 Invacare® Matrx® PB Elite
3 Setup
3.1 Hardware Kit Contents
3.2 Tools Required
3.3 Before Installation
Mounting Configuration
The mounting plates are shipped pre-assembled on the cane clamps in the rearmost mounting
configuration. This maximizes the seat depth on the wheelchair seat (up to a maximum 2.5” (64 mm)
rearward offset - see image A).
By changing the orientation of the mounting plates on the cane clamps, the assembly can be reconfigured*
to provide a more forward mounting position for the back if desired (up to a maximum 2.5” (64 mm)
forward offset - see image B).
*To reconfigure a mounting plate/cane clamp to
the forwardmost orientation:
1. Detach the mounting plate from the cane clamp
(3 screws);
2. Rotate the cane clamp 180° and re-fasten it to
mounting plate;
3. Install cane clamp as illustrated in image B.
Hardware is sold separately.
If any of the hardware is missing or misplaced, please contact our customer service department
and arrangements will be made to send you the necessary replacements. Refer to Contact
Information on page 179.
QTY DESCRIPTION
2 Back Mounting Plates
2 Cane Clamps
2 Cane Inserts (1” (25 mm))
2 Cane Inserts (7/8” (22 mm))
6 Depth/Recline Adjustment Screws
6 Cane Clamp Screws
2Set Screws
2 Cane Clamp Nut Plates
4 Long Mounting Pins (optional)
Wrenches: 7/8” (22 mm) Phillips Screwdriver
Allen Keys: (provided) Tape Measure/Ruler
Utility Knife/Scissors
Back
Mounting
Plate
Cane
Clamp
Nut
Plate
Depth/Recline
Adjustment
Screws
Cane Insert
Cane
Clamp
Set
Screw
Cane
Clamp
Screws
WARNING
When establishing the mounting position for the Invacare Matrx Elite, ensure the stability of the
wheelchair is not compromised.
Adjusting the forward and aft position of the backrest will alter the user’s center of gravity within
the wheelchair. A recessed back position can significantly reduce the rearward stability of the
wheelchair. Similarly, a more forward back position will reduce the wheelchair’s forward stability.
Each mounting plates is also designed to provide 1.5” (38 mm) of fore and aft adjustment
relative to the cane clamp
Front of Wheelchair
A
B
Mounting plate in
rearmost back position
(maximized seat depth)
Mounting plate in
forwardmost back
position
Front of Wheelchair
Invacare® Matrx® PB Elite 6 Part No 1176089
Accommodating Back Cane Size
1” (25 mm) back cane - Cane clamps are
installed without plastic inserts.
7/8” (22 mm) back cane - Requires 7/8” (22
mm) plastic inserts (provided)
3/4” (19 mm) back cane - Requires 3/4” (19
mm) plastic inserts
On some wheelchairs, there may be an uneven seam along the back posts where a smaller
diameter tube is inserted into a larger diameter tube. If the cane clamps must be mounted over
this seam, the plastic inserts may be cut in half to allow the clamp to fasten securely onto the back
posts (see image B).
For wheelchairs with short back canes, it may be necessary to install Matrx PB Cane
Replacements (PBCR’s). The PBCR’s are designed to replace existing push handles or cane
extensions on standard 1” (25 mm) back posts. The cane clamps can be mounted directly
onto the replacement back canes in order to allow proper installation of the Invacare Matrx Elite.
Cane replacements are available from Motion Concepts (part#-TRX2810).
Plastic Insert
A
B
The plastic insert may be cut if
the cane clamp is secured at
the junction of 2 different
diameter back posts.
PBCR
Part No 1176089 7 Invacare® Matrx® PB Elite
3.4 Installing the Invacare Matrx Elite
Installing the Mounting Plates
1. Remove existing wheelchair back upholstery (if
applicable).
2. Establish the desired mounting plate set-
up/configuration for the user. Refer to Before
Installation on page 5.
3. Loosen cane clamp screws (x3) and loosely
install the cane clamp (with mounting bracket)
onto each back post. (Install plastic inserts if
required).
4. Starting on one side, position the cane clamp at
the desired height on the back post and tighten
the clamp screws enough to hold it in place.
Clamps and set screws will be fully tightened
after the back is installed and all final adjustments
have been made.
5. From a fixed point on the wheelchair (e.g. seat
frame) measure the exact height of the installed
cane clamp assembly, and install the second cane
clamp at the same height on the opposite back
post - see image A on page 7. Ensure the cane
clamps/mounting plates are mounted parallel
with each other.
6. To install the Invacare Matrx Elite onto the
mounting plates:
A. Slide the lower mounting pins into the
hooked slots at the bottom of each
mounting plate (see image B).
B. With the lower pins in place, lock/snap
the upper mounting pins into the latch
mechanism at the top of the mounting
plates.
WARNING
The installation hardware provided is
high strength and tested for durability.
DO NOT substitute hardware. Use only
the hardware supplied.
Additional upper and lower adjustment
slots are provided on the mounting
plate to allow alternate mounting
heights if obstacles are encountered.
Using these alternate mounting slots will
increase or decrease the back height by
7/8” (22 mm). These alternate slots will
limit the range of available depth and/or
recline angle adjustment.
1
2
Cane
Clamps
Install cane clamps at
equal heights and parallel
to each other.
Front view of wheelchair with
back removed
Upper
Adjustment
Slot
Mounting
Plate
Lower
Adjustment
Slot
A
B
Lower
Mounting
Pin
Upper
Mounting
Pin
Invacare® Matrx® PB Elite 8 Part No 1176089
Mounting Pin Configurations/Setup
Mounting Pin Adjustment
1. With the back secured in place on the
wheelchair, determine the amount of
adjustment required for each mounting pin (see
figure).
2. Remove the backrest from the wheelchair and
use a wrench to loosen the flange nut on each
pin that requires adjustment. If necessary,
replace the standard mounting pins with long
mounting pins.
3. Adjust the mounting pin depth (clockwise to
shorten/counter-clock wise to lengthen) so that
a minimum gap of 1/8” (3mm) exists between
the top of the pin and the mounting plate.
4. Re-tighten each flange nut to secure the pins in
place.
Invacare Matrx Elite backs are available in a range of widths (12” (31 cm) - 20” (51 cm)) and 6
different heights (10” (26 cm); 12” (31 cm); 14” (36 cm); 16” (41 cm); 18” (46 cm) and 20” (51
cm)). Due to variances that exist between different wheelchair manufacturers, the depth of the
mounting pins may require some adjustment to properly fit the Invacare Matrx Elite onto the
wheelchair back posts. Refer to Mounting Pin Adjustment on page 8. Two sets of mounting pins
are supplied with every Invacare Matrx Elite (standard pins and long pins). The standard pins are
installed at the factory and are suitable for most typical wheelchair configurations. The long pins
are designed to allow installation onto back posts that are up to 1” (25 mm) wider than the width
of the actual backrest.
*Elite back widths are offered in 1” (25 mm) increments).
Example: for a 16" (41 cm) Invacare Matrx Elite:
16" (41 cm) wheelchair seat frame (back post)
width = standard pins
17" (43 cm) wheelchair seat frame (back post)
width = long pins
When the narrowest setting is used for the back,
the depth/recline range will be less than in wider
positions.
Extended Mounting Pins (EMP) are available (sold separately) to allow interfacing of our Invacare
Matrx Elite backs onto wheelchair seat frames up to 2” (5 cm) wider than the actual back width.
CAUTION
* EMP’s are only for use with our standard back sizes (for up to 300lb (136 kg) weight capacity);
EMP’s are not recommended for use in tilt applications.
Rear View
Mounting
Pins (x 4)
Adjustable
Pin Depth
CAUTION
Improper pin set-up may cause damage to the back pan and/or the mounting plates. Ensure
sufficient spacing is provided between the mounting plates and the mounting pins (a min. gap of
1/8” (3mm) is recommended).
Ensure flange nuts are fully tightened; Failure to do so may cause damage/cracking in the back pan.
Ensure pins do not rotate when tightening the flange nuts. NEVER use Loctite® on mounting pin
hardware.
Standard
Mounting Pin
Flange Nut
Back Pan
1/8” (3 mm) min. gap
(optional)
Long Mounting Pin
Mounting Plate
Part No 1176089 9 Invacare® Matrx® PB Elite
Installing the Back
1. Verify that the overall fit and alignment of the
back is correct (make adjustments as needed).
2. Fully secure the cane clamp screws onto both
back posts, and tighten the set screws to ensure
the mounting plates do not slip or rotate.
3. To best determine the optimal depth and recline
settings for the back, the user should be seated
in the wheelchair. While seated, loosen the
depth/recline screws on the mounting plates and
adjust the back to the desired depth and recline
angle. Re-tighten all screws to lock the back in
position.
4 Usage
4.1 Disengaging the Back from the Wheelchair
1. Perform one of the following:
No Cord Release Mechanism -
Simultaneously lift the release levers
(left and right) to unlock the latch
mechanism and release the upper pins
from the mounting plates. Refer to the
figure.
Cord Release Mechanism - Lift cord
upward to unlock/open the release
levers. Refer to One-Hand Cord
Release Mechanism on page 10.
2. Lift entire backrest up and forward to disengage
the lower pins from the lower slots in the
mounting plates.
Ensure that the depth/recline
adjustment for the back is made
symmetrically* on the left and right
mounting plates.
The vertical score lines on the mounting
plates are designed as a point of
reference to assist with symmetrical
mounting (see image). Since the back
can be mounted in a rotated (reclined)
position if desired, it will not always be
mounted parallel with these vertical
lines.
.
2
1
Upper Mounting Pin
Lower
Mounting
Pin
Release
Lever
Invacare® Matrx® PB Elite 10 Part No 1176089
4.2 Lateral Supports (Optional)
Lateral Pads are available from Motion Concepts
as an option for additional lateral support. Lateral
Pads are offered in small, large and offset styles
(see Figure). Mounting slots in the back shell and
the lateral support brackets allow for adjustment
both vertically and laterally. Upper and lower
mounting slots are provided on the back pan for
an even greater range of adjustment. Lateral
Supports may be further customized by carefully
bending* the lateral to a more desirable contour/
position for the client. Refer to Installing Lateral
Supports.
Installing Lateral Supports
1. Pull up the bottom of the cover (release hook
and loop fasteners) to expose the mounting
slots/channels in the back pan.
2. Determine the desired mounting
height/orientation for the lateral pads (upper or
lower mounting slot position).
3. If applicable, carefully bend the lateral support(s)
to the desired contour (prior to installation).
4. Loosely install the lateral supports onto the back
pan using the hardware provided.
5. Adjust laterals to the desired position via the
mounting slots on the backpan and via the slots
in the lateral support bracket. Secure each
lateral support into place.
6. Re-attach the back cover via the hook and loop
fasteners.
4.3 One-Hand Cord Release Mechanism
1. Thread the nylon cord through the holes in the latch mechanism at the top of the left and right
mounting plates (see image A)
2. Install the cord lock mechanism onto the cord (see image B). Press the button to open the lock
mechanism and slide the two open ends of the nylon cord through the opening.
3. With the back properly installed on the wheelchair, adjust the cord length so that it hangs at
approximately a 45° angle along the back pan (this allows the release mechanism to operate more
effectively). If necessary, cut/remove excess cord to eliminate any risk of entanglement. Once
adjusted, combine the loose cord ends into a single knot to prevent the cord-lock from slipping.
WARNING
*For best results and to prevent damage,
the lateral supports must be removed
from the back pan prior to bending
Hardware can be installed in either
orientation on the back pan (with the
backing plates located on the inside
or outside of the back pan). The
standard mounting orientation is
shown at right.
Standard Lateral (large)
Standard Lateral (small)
Offset Lateral
Offset laterals may be mounted to the
back pan in either orientation (as
shown) to provide extended support.
Lateral Support
Bracket
Spacer
Spacers are only required when
using the upper slot on the back pan.
Front
Backing Plate
Lower
Mounting
Slots
Upper
Mounting
Slots
Rear
3” (76 mm)
Lower mounting slots not available
on 10” (26 cm) or 12” (31 cm) high
Invacare Matrx Elite backs.
Part No 1176089 11 Invacare® Matrx® PB Elite
4.4 Lumbar Support (Optional)
Lumbar Support Adjustment
1. To access the Lumbar Support, open the hook
and loop fastening strips on the outer cover at
the bottom rear of the back pan.
2. The foam lumbar support/ insert is installed
inside the Invacare Matrx Elite cover between
the foam back cushion and the back pan (see
image B)
3. The lumbar support can be adjusted manually to
any desired height/position.
4. Refasten the cover onto the back pan.
5 Care and Maintenance
5.1 Cleaning
The cover may be easily wiped down with a damp cloth when necessary. The cover can be removed for
laundering or providing access to the inside of the back for modification. Carefully remove the cover by
releasing the hook and loop fasteners along the top and bottom edge and inside of the back shell. Remove
the inner foam cushion from the cover prior to laundering.
In the event of the cover becoming contaminated, please ask your Infection Control Officer for advice.
Alternatively, contact Invacare for their information on decontamination protocol.
If the cord length was modified, carefully melt the ends of the cord to prevent fraying.
Thread cord through the latch mechanism.
A
B
Tie a knot using both
cord ends.
Melt cord ends to prevent fraying.
Press button to
open/adjust.
Cord
Lock
45°
Installed Back
Lift cord to
release back
cushion.
The Lumbar Support is a pre-
fabricated foam insert that provides
lower back support for additional
comfort. The position of the lumbar
insert can be adjusted inside the
Invacare Matrx Elite cover, or it may
be removed if no lumbar support is
desired
Hook and loop fastening strip
Foam Cushion
Front
Lumbar
Support
B
A
Lumbar Support
Foam Cushion
Invacare® Matrx® PB Elite 12 Part No 1176089
5.2 Inspection
Visually inspect parts including hardware, brackets, upholstery materials, foams (if accessible), and
plastics, for deformation, corrosion, breakage, wear or compression.
6 After Use
6.1 Reuse
The back cushion is suitable for re-use. The following actions should be taken:
Cleaning and disinfection according to Cleaning on page 11.
Inspection according to Inspection on page 12.
The back cushion should be adapted for the new user in according to Installing the Back on page 9,
Installing Lateral Supports
on page 10 and Lumbar Support Adjustment on page 11.
7 Warranty
This warranty is extended only to the original purchaser/user of our products.
This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state.
Invacare/Motion Concepts warrants this product to be free from defects in materials and workmanship for two years of use by
original purchaser. This warranty does not apply to punctures, tears or burns, nor to the removable cushion cover. If within such
warranty period any such product shall be proven to be defective, such product shall be repaired or replaced, at
Invacare's/Motion Concepts’ option, with refurbished or new parts. This warranty does not include any labor or shipping charges
incurred in replacement part installation or repair of any such product. Product repairs shall not extend this warranty - coverage
for repaired product shall end when this limited warranty terminates. Invacare's/Motion Concepts’ sole obligation and your
exclusive remedy under this warranty shall be limited to such repair and/or replacement.
For warranty service, please contact the dealer from whom you purchased your Invacare/Motion Concepts product. In the event
you do not receive satisfactory warranty service, please write directly to Invacare/Motion Concepts at the address on the back
cover. Provide dealer's name, address, model number, the date of purchase, indicate nature of the defect and, if the product is
serialized, indicate the serial number.
Invacare Corporation/Motion Concepts will issue a return authorization. The defective unit or parts must be returned for
warranty inspection using the serial number, when applicable, as identification within thirty (30) days of return authorization date.
DO NOT return products to our factory without our prior consent. C.O.D. shipments will be refused; please prepay shipping
charges.
LIMITATIONS AND EXCLUSIONS: THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NORMAL
WEAR OR FAILURE TO ADHERE TO THE ENCLOSED INSTRUCTIONS. IN ADDITION, THE FOREGOING
WARRANTY SHALL NOT APPLY TO SERIAL NUMBERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED
OR DEFACED; PRODUCTS SUBJECTED TO NEGLIGENCE, ACCIDENT, IMPROPER OPERATION, MAINTENANCE OR
STORAGE; OR PRODUCTS MODIFIED WITHOUT INVACARE'S/MOTION CONCEPTS’ EXPRESS WRITTEN CONSENT
INCLUDING, BUT NOT LIMITED TO: MODIFICATION THROUGH THE USE OF UNAUTHORIZED PARTS OR
ATTACHMENTS: PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE
SPECIFIC CONSENT OF INVACARE/MOTION CONCEPTS; PRODUCTS DAMAGED BY CIRCUMSTANCES BEYOND
INVACARE'S/MOTION CONCEPTS’ CONTROL; PRODUCTS REPAIRED BY ANYONE OTHER THAN AN
INVACARE/MOTION CONCEPTS DEALER, SUCH EVALUATION SHALL BE SOLELY DETERMINED BY
INVACARE/MOTION CONCEPTS.
THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES, IF ANY,
INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
IT SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESSED WARRANTY PROVIDED HEREIN AND THE
REMEDY FOR VIOLATIONS OF ANY IMPLIED WARRANTY SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE
DEFECTIVE PRODUCT PURSUANT TO THE TERMS CONTAINED HEREIN. INVACARE/MOTION CONCEPTS SHALL
NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER.
THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE/PROVINCIAL LAWS AND REQUIREMENTS.
WARNING
Check ALL fasteners weekly to ensure that mechanical connections and attaching hardware are
tightened securely - otherwise injury or damage may occur.
DO NOT continue to use this product if problems are discovered. Corrective maintenance can
be performed at or arranged through your equipment supplier.
WARNING: Risk of Injury
Always have a dealer inspect the product for damage before transferring the product to a different
user. If any damage is found, DO NOT use the product. Otherwise injury may occur.
Réf. 1176089 13 Invacare® Matrx® PB Elite
Invacare® Matrx® PB Elite
Modèles PBE, PBE-FB et EDB
1 Généralités
1.1 Pictogrammes
Les mots d’avertissement utilisés dans le présent manuel s’appliquent aux risques ou aux pratiques
dangereuses qui pourraient provoquer des blessures ou des dommages matériels. Voir les informations
ci-dessous pour la définition des mots d’avertissement.
1.2 Aperçu
Informations importantes
La meilleure façon d’éviter les problèmes liés aux escarres est d’en comprendre les causes et votre rôle
dans un programme de soins dermatologiques.
Demandez l’avis de votre thérapeute ou de votre médecin si vous avez des questions concernant vos
restrictions et besoins individuels.
Tous les coussins doivent être choisis avec soin. La collaboration avec votre thérapeute et votre médecin
constitue la meilleure façon de s’assurer qu’un coussin correspond bien à vos besoins.
Plus les besoins individuels sont complexes, plus le choix du coussin est important.
Invacare Matrx Elite
Le dossier Invacare Matrx Elite est contouré pour offrir une orientation précise dans le fauteuil roulant
afin d’obtenir un soutien optimal. La mousse est surdimensionnée pour offrir un confort et une
protection accrus.
Le dossier Invacare Matrx Elite inclut une garniture en mousse de soutien lombaire amovible à
installer/insérer derrière le coussin en mousse existant pour fournir un positionnement encore amélioré.
Reportez-vous à Soutien lombaire (en option) à la page 25. pour les instructions sur la mise en place et
l’ajustement du maintien lombaire.
Housse extérieure
La housse extérieure est réalisée en tissu maille de filet, résistant à l’humidité et respirant. Il est conseillé
de nettoyer et d’inspecter régulièrement la housse extérieure. Reportez-vous à Entretien et maintenance
à la page 25.
AVERTISSEMENT
Avertissement indique une situation potentiellement dangereuse qui pourrait provoquer des
blessures graves ou la mort.
ATTENTION
La mention Attention indique une situation potentiellement dangereuse qui, si elle n’est pas évitée,
peut entraîner des dommages et/ou des blessures légères.
Donne des conseils, recommandations et informations utiles pour une utilisation efficace et sans
souci.
Manuel d’utilisation
REVENDEUR : Ce manuel DOIT être remis à l’utilisateur du
produit.
UTILISATEUR :
AVANT l’utilisation du produit, lisez ce manuel et
conservez-le pour référence.
Invacare® Matrx® PB Elite 14 Réf. 1176089
2 Sécurité
2.1 Transport du client dans un fauteuil roulant équipé d’un dossier Matrx Back
dans un véhicule motorisé
Les directives suivantes doivent être mises à disposition de toutes les parties responsables du transport
du client, telles que les écoles et entreprises de transport.
Dès que c’est possible, le client doit être transféré hors du fauteuil roulant sur un siège de véhicule et
attaché avec une ceinture trois points ou être assis dans un siège auto pour enfants adapté.
Le dossier Matrx a été testé de manière dynamique et répond aux exigences de la norme ISO 16840-4
et Section 20, ANSI/RESNA WC/Volume 4 “Systèmes
dassisedanslesvéhiculesàmoteurs”.UnsubstitutdebasedefauteuilroulantetundispositifdetesthybrideIIIanthr
opomorphiquedelataillemoyenned’unhommeadulteontétéutiliséslorsd’untestd’impactfrontal.Lesubstitutd
ebasedefauteuilroulantétaitsécuriséparunlienàquatrepointsdetypestrapetl’occupantétaitattachéparunsyst
èmederetenueventraletdiagonal.'
Les dossiers Matrx doivent être utilisés uniquement en combinaison avec des fauteuils roulants répondant
aux exigences de performances de la norme ANSI WC19 ou ISO 7176-19.
Avant de monter dans le véhicule, vérifiez les points suivants :
Dossier Matrx – doit être fixé dans le fauteuil roulant comme décrit dans le Manuel d’utilisation.
Ceintures de maintien et harnais – doivent rester en place durant le transport, bien qu’ils soient prévus
uniquement pour offrir un maintien, ils ne servent pas à la sécurité durant le transport.
Appui-te – doit être fixé et bien ajusté près de l’arrière de la tête du client durant le transport, afin de
réduire le risque de blessures par coup de fouet cervical.
Système d’attache du fauteuil roulant et système de retenue de l’occupant
Fixation du fauteuil roulant – le fauteuil roulant doit être fixé dans le véhicule, face vers l’avant, dans le
respect des instructions des fabricants du fauteuil roulant et du système dattache.
Retenue de l’occupant – un système de retenue de l’occupant doit aussi être installé en accord avec les
instructions du fabricant. L’équipement minimum est une ceinture ventrale et diagonale (une ceinture
ventrale seule ne suffit pas). Evitez les systèmes de retenue qui font une boucle au-dessus de l’épaule et
s’ancrent au plancher du véhicule, car ils peuvent constituer une charge importante vers le bas à travers
le client durant un impact. Privilégiez une attache au-dessus et derrière l’épaule comme avec une ceinture
de sécurité de voiture. La partie ventrale de la ceinture doit être ajustée sur le pelvis du client et ne doit
pas remonter sur l’abdomen. La section de la ceinture placée en haut du torse doit être en contact avec
la poitrine du client et passer sur l’épaule, sans couper le cou ni glisser de l’épaule.
2.2 Utilisation conforme
Le dossier Invacare Matrx Elite est conçu pour offrir une orientation précise dans le fauteuil roulant afin
d’obtenir un soutien optimal.
Vérifiez l’absence de dommages dus au transport sur TOUTES les pièces. Si vous constatez un
dommage dû au transport, N’UTILISEZ PAS le produit. Contactez le transporteur/revendeur
pour connaître la marche à suivre.
En cas de transport à vide du fauteuil roulant et du dossier Matrx, attachez le fauteuil avec un
équipement adéquat correspondant aux instructions du fabricant. Si l’équipement doit être
dsassemblé pour le transport, assurez-vous que toutes les pièces sont fixées en toute sécurité
dans le véhicule.
Réf. 1176089 15 Invacare® Matrx® PB Elite
2.3 Avertissements généraux
AVERTISSEMENT
NE PAS UTILISER CE PRODUIT OU TOUT AUTRE ÉQUIPEMENT DISPONIBLE EN OPTION
SANS AVOIR LU ET COMPRIS COMPLÈTEMENT CES INSTRUCTIONS ET TOUTE AUTRE
DOCUMENTATION D’INSTRUCTIONS SUPPLÉMENTAIRE, TELLE QUE LES MANUELS
D’UTILISATION, LES MANUELS
DENTRETIENOUFEUILLESD'INSTRUCTIONSFOURNIESAVECCEPRODUITOUL’ÉQUIPEME
NTENOPTION.SIVOUSNECOMPRENEZPASLESAVERTISSEMENTS,MISESENGARDEOUINST
RUCTIONS,CONTACTEZUNPROFESSIONNELDESANTE,REVENDEUROUTECHNICIENAV
ANTD'ESSAYERD'UTILISERCETÉQUIPEMENT,SOUSPEINEDEDOMMAGES.'
AVERTISSEMENT ACCESSOIRES
Les produits Invacare sont spécialement conçus et fabriqués pour être utilisés en combinaison
avec les accessoires Invacare. Les accessoires conçus par d’autres fabricants n’ont pas ét testés par
Invacare et leur utilisation avec les produits Invacare est déconseillée.
AVERTISSEMENT RELATIF À L’INSTALLATION
Les procédures décrites dans le présent manuel doivent être effectuées par un technicien qualifié.
Avant tout réglage, toute réparation ou maintenance et avant usage, assurez-vous que les pièces
sont toutes bien en place.
N’installez PAS l’ensemble Invacare Matrx Elite sur des cannes de dossier dont le diamètre
extérieur dépasse 1 pouce ou n’atteint pas ¾ pouce. Sinon, il y a un risque de blessure ou de
dommage.
La position de montage de l’Invacare Matrx Elite est en relation directe avec la stabilité du fauteuil.
L’ajout de l’Invacare Matrx Elite sur un fauteuil à BASCULEMENT et/ou INCLINAISON peut
entraîner une baisse de stabilité du fauteuil. Il peut s’avérer nécessaire de repositionner les
ROULETTES AVANT, les ROUES ARRIERE, L’ANGLE DU DOSSIER, L’ESPACE DE
BASCULEMENT, L’INCLINAISON et/ou la PROFONDEUR DU SIEGE avant utilisation. Soyez
très prudents avant d’utiliser une nouvelle position d’assise.
Lors de l’ajout du Matrx Elite sur un fauteuil à BASCULEMENT et/ou INCLINAISON, une BARRE
RIGIDE ou une BARRE TRANSVERSALE doit être présente afin de stabiliser les cannes de
dossier.
Assurez-vous que l’Invacare Matrx Elite est bien fixé au fauteuil roulant avant utilisation. Sinon, il y
a un risque de blessure ou de dommage.
AVERTISSEMENT
Vérifiez très fréquemment l’état de la peau après l’installation d’un nouveau système d’assise.
Demandez l’avis de votre thérapeute ou de votre médecin si vous avez des questions concernant
vos restrictions et besoins individuels.
La collaboration avec votre thérapeute, votre médecin et votre fournisseur d’équipements
constitue la meilleure façon de s’assurer qu’un système d’assise correspond bien à vos besoins.
Plus les besoins individuels sont complexes, plus le choix de l’assise est important.
Invacare® Matrx® PB Elite 16 Réf. 1176089
2.4 Restriction de poids et références des modèles
Reportez-vous au tableau pour connaître les restrictions de poids et les références de modèles.
PBE = Matrx Elite Back, PBE-FB = Matrx Elite Full Back, EDB = Matrx Elite Deep Back
gris = tailles indisponibles
LARGEUR HAUTEUR
PROFONDEUR
DU CONTOUR
LIMITE DE POIDS
25 CM 30 CM 36 CM 41 CM 46 CM 51 CM
30 cm PBE3126-NH
1545083
PBE3131-NH
1545084
PBE3136-NH
1545085
PBE3141-NH
1545086
PBE3146-NH
1545087
8 cm 136 kg
33 cm PBE3326-NH
1545088
PBE3331-NH
1545089
PBE3336-NH
1545090
PBE3341-NH
1545091
PBE3346-NH
1545092
8 cm
36 cm PBE3626-NH
1545093
PBE3631-NH
1545094
PBE3636-NH
1545095
PBE3641-NH
1545096
PBE3646-NH
1545097
PBE3651-NH
1545098
8 cm
EDB3631-NH
1543504
EDB3641-NH
1543505
EDB3646-NH
1543506
EDB3651-NH
1543507
15 cm
38 cm PBE3826-NH
1545099
PBE3831-NH
1532092
PBE3841-NH
1532093
PBE3846-NH
1545100
PBE3851-NH
1532094
8 cm
EDB3831-NH
1543508
EDB3841-NH
1543509
EDB3846-NH
1543510
EDB3851-NH
1543511
15 cm
41 cm PBE4126-NH
1545101
PBE4131-NH
1515719
PBE4141-NH
1515720
PBE4146-NH
1545102
PBE4151-NH
1517754
8 cm
EDB4131-NH
1543512
EDB4141-NH
1543513
EDB4146-NH
1543514
EDB4151-NH
1543515
15 cm
PBE4151-FB-NH
1545103
8 cm
43 cm PBE4326-NH
1545104
PBE4331-NH
1515721
PBE4341-NH
1515722
PBE4346-NH
1545105
PBE4351-NH
1517755
8 cm
EDB4331-NH
1543516
EDB4341-NH
1543517
EDB4346-NH
1543518
EDB4351-NH
1543519
15 cm
PBE4351-FB-NH
1545106
8 cm
46 cm PBE4626-NH
1545107
PBE4631-NH
1515723
PBE4641-NH
1515724
PBE4646-NH
1545108
PBE4651-NH
1517756
8 cm
EDB4631-NH
1543520
EDB4641-NH
1543521
EDB4646-NH
1543522
EDB4651-NH
1543523
15 cm
PBE4651-FB-NH
1545109
8 cm
48 cm PBE4826-NH
1545110
PBE4831-NH
1515725
PBE4841-NH
1515726
PBE4846-NH
1545111
PBE4851-NH
1517757
8 cm
EDB4831-NH
1543524
EDB4841-NH
1543525
EDB4846-NH
1543526
EDB4851-NH
1543987
15 cm
PBE4851-FB-NH
1545112
8 cm
51 cm PBE5126-NH
1545113
PBE5131-NH
1532095
PBE5141-NH
1532096
PBE5146-NH
1545114
PBE5151-NH
1532097
8 cm
EDB5131-NH
1543988
EDB5141-NH
1543989
EDB5146-NH
1543990
EDB5151-NH
1543991
15 cm
PBE5151-FB-NH
1545115
8 cm
Réf. 1176089 17 Invacare® Matrx® PB Elite
3 Installation
3.1 Contenu du kit
3.2 Outils requis
3.3 Avant l’installation
Configuration de montage
Les plaques de fixation sont expédiées préassemblées sur les clames de cannes dans la configuration de
montage la plus reculée. Ceci augmente la profondeur d’assise sur le fauteuil (décalage arrière maximum
2.5” (64 mm) - voir image A).
En changeant l’orientation des plaques de fixation sur les clames de cannes, l’assemblage peut être
reconfiguré* afin de fournir une position de montage plus avancée pour le dos si souhait (décalage avant
maximum 2.5” (64 mm) - voir image B).
*Pour reconfigurer une plaque de fixation/une
clame de canne sur la position la plus avancée :
1. Détachez la plaque de fixation de la clame de
canne (3 vis) ;
2. Faites tourner la clame de canne de 180° et
refixez-la à la plaque de fixation ;
3. Installez la clame de canne comme illustré par
l’image B.
Le matériel est vendu séparément.
Si du matériel est manquant ou mal placé, veuillez contacter notre service client qui fera le
nécessaire pour vous envoyer les pièces détachées. Reportez-vous à Informations de contact à la
page 179.
QTÉ DESCRIPTION
2 Plaques de fixation de dossier
2Clames de cannes
2 Inserts de cannes (1” (25 mm))
2 Inserts de cannes (7/8” (22 mm))
6 Vis de réglage de profondeur/inclinaison
6Vis à clames de cannes
2Vis de réglage
2 Plaques d’écrous à clames de cannes
4 Broches de fixation longues (option)
Clés : 7/8” (22 mm) Tournevis Phillips
Clés Allen : (fournies) Ruban à mesurer/Règle
Couteau/Ciseaux
Plaque de
fixation de
dossier
Plaque
d’écrou à
clame de
canne
Vis de
réglage de
profondeur/
inclinaison
Insert de canne
Clame de
canne
Vis de
réglage
Vis à
clames de
cannes
AVERTISSEMENT
Lors du choix de la position de montage de l’Invacare Matrx Elite, assurez-vous de la stabilité du
fauteuil.
L’ajustement de la position avant et arrière du dossier modifie le centre de gravité de l’utilisateur
dans le fauteuil roulant. Une position reculée vers l’arrière peut réduire sensiblement la stabilité
arrière du fauteuil roulant. De la même manière, une position avancée réduit la stabilité avant du
fauteuil roulant.
Chaque plaque de fixation est aussi
conçue pour fournir 1.5" (38 mm)
d’ajustement avant et arrière
relativement à la clame de canne
Avant du fauteuil
roulant
A
B
Plaque de fixation dans la
position de dossier la plus
reculée (profondeur
d’assise maximale)
Plaque de fixation
dans la position de
dossier la plus
avancée
Avant du fauteuil
roulant
Invacare® Matrx® PB Elite 18 Réf. 1176089
Ajustement de la taille des cannes de dossier
Canne de dossier 1” (25 mm) – les clames de
cannes s’installent sans les inserts plastiques.
Canne de dossier 7/8” (22 mm) – nécessite
des inserts plastiques 7/8” (22 mm) (fournis)
Canne de dossier 3/4” (19 mm) – nécessite
des inserts plastiques 3/4” (19 mm)
Certains fauteuils roulants peuvent présenter une couture irrégulière le long des montants arrière
où un tube de diamètre inférieur est inséré dans un tube de diamètre supérieur. Si les clames de
cannes doivent être montées sur cette couture, les inserts plastiques peuvent être coupés pour
permettre de fixer les clames de manière sûre aux montants arrière (voir image B).
Pour les fauteuils à cannes de dossier courtes, il peut être nécessaire d’installer des Matrx PB
Cane Replacements (PBCR). Les PBCR sont conçus pour remplacer les poignées ou les
extensions de cannes existantes sur les montants arrière standard 1” (25 mm). Les clames
de cannes peuvent être
montées directement sur les cannes de dossier de rechange, afin de
permettre une installation correcte de l’Invacare Matrx Elite. Des cannes de rechange sont
disponibles auprès de Motion Concepts (réf. TRX2810).
Insert plastique
A
B
L’insert plastique peut être
découpé si la clame de
canne est fixée à la jonction
de 2 montants arrière de
diamètres différents.
PBCR
Réf. 1176089 19 Invacare® Matrx® PB Elite
3.4 Installation de l’Invacare Matrx Elite
Installation des plaques de fixation
1. Déposez la sellerie de dossier du fauteuil roulant
(si applicable).
2. Etablissez le réglage/la configuration de la plaque
de fixation souhaités pour l’utilisateur. Reportez-
vous à Avant l’installation
à la page 17.
3. Dévissez les vis des clames de cannes (x3) et
installez la clame de canne (sans la bride de
montage) sur chaque montant arrière sans
serrer. (Installez des inserts plastiques si
nécessaire).
4. En commençant d’un côté, positionnez la clame
de canne à la hauteur voulue sur le montant
arrière et vissez les vis de clame suffisamment
pour la maintenir en place. Les clames et vis de
rglage doivent être serrées à fond après
l’installation du dossier et une fois tous les
réglages finaux effectués.
5. A partir d’un point fixe sur le fauteuil roulant (p.
ex. châssis), mesurez la hauteur exacte de
l’assemblage de clame de canne installé et
installez la deuxième clame de canne à la même
hauteur sur le montant arrière opposé – voir
image A, page 19. Assurez-vous que les clames
de cannes/plaques de fixation sont montées
parallèlement les unes aux autres.
6. Pour installer l’Invacare Matrx Elite sur les
plaques de fixation :
A. Faites glisser les broches de fixation
inférieures sur les fentes à crochet au
bas de chaque plaque de fixation (voir
image B).
B. Avec les broches de fixation inférieures
en place, verrouillez/enclenchez les
broches supérieures dans le mécanisme
de verrouillage en haut des plaques de
fixation.
AVERTISSEMENT
Le matériel d’installation fourni est très
robuste et sa durabilité est éprouvée.
NE remplacez PAS le matériel. Utilisez
exclusivement le matériel fourni.
Des fentes de réglage inférieures et
supérieures supplémentaires sont
fournies sur la plaque de fixation pour
permettre d’ajuster les hauteurs de
fixation en cas d’obstacles. L’utilisation
de ces fentes de fixation alternatives
augmente ou réduit la hauteur du
dossier de 7/8” (22 mm). Ces fentes
alternatives limitent la plage de réglage
de la profondeur et/ou de l’angle
d’inclinaison.
1
2
Clames
de
cannes
Installez les clames de cannes à
la même hauteur et parallèles
l’une à l’autre.
Vue avant du fauteuil roulant
avec le dossier déposé
Fente de
réglage
supérieure
Plaque de
fixation
Fente de
réglage
inférieure
Broche de
fixation
supérieure
Broche de
fixation
inférieure
A
B
Invacare® Matrx® PB Elite 20 Réf. 1176089
Configurations/réglage des broches de fixation
Nos dossiers Invacare Matrx Elite sont disponibles dans des diverses largeurs 12” (31 cm) - 20”
(51 cm)) et 6 hauteurs (10” (26 cm); 12” (31 cm); 14” (36 cm); 16” (41 cm); 18” (46 cm) and 20”
(51 cm)). En raison des variations entre différents fabricants de fauteuils roulants, la profondeur
des broches de fixation peut nécessiter un ajustement pour la bonne fixation de lInvacare Matrx
Elite sur les montants arrière du fauteuil roulant. Reportez-vous à Réglage des broches de fixation
à la page 21.. Deux kits de broches de fixation sont fournis avec chaque Invacare Matrx Elite
(broches standard et longues). Les broches standard sont installées en usine et s’adaptent à la
plupart des configurations de fauteuils roulants courantes. Les broches longues sont conçues pour
permettre l’installation sur les montants arrière jusqu’à 1” (25 mm) plus larges que la largeur du
dossier.
*les largeurs des dossiers Elite sont proposées par incréments de 1” (25 mm)).
Exemple : pour un Invacare Matrx Elite 16" (41
cm) :
largeur châssis d’assise de fauteuil 16” (41 cm)
(montant arrière) = broches standard
largeur châssis d’assise de fauteuil 17” (43 cm)
(montant arrière) = broches longues
Lorsque le réglage le plus étroit est utilisé pour le
dossier, la plage de profondeur/d’inclinaison sera
moindre que pour les positions plus larges.
Des broches de fixation étendues* (EMP) sont disponibles (vendues séparément) pour permettre
l’utilisation de nos dossiers Invacare Matrx Elite sur les châssis d’assise de fauteuil jusquà 2” (5 cm)
plus larges que la largeur réelle du dossier.
ATTENTION
* Les EMP sont conçus uniquement pour une utilisation avec nos tailles de dossiers standard (avec
une capacité de 300 lb (136 kg) maximum) ; les EMP ne sont pas conseillés pour une utilisation
dans les applications à basculement.
Vue
arrière
Broches
de fixation
(x4)
Profondeur
réglable
des
broches
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144
  • Page 145 145
  • Page 146 146
  • Page 147 147
  • Page 148 148
  • Page 149 149
  • Page 150 150
  • Page 151 151
  • Page 152 152
  • Page 153 153
  • Page 154 154
  • Page 155 155
  • Page 156 156
  • Page 157 157
  • Page 158 158
  • Page 159 159
  • Page 160 160
  • Page 161 161
  • Page 162 162
  • Page 163 163
  • Page 164 164
  • Page 165 165
  • Page 166 166
  • Page 167 167
  • Page 168 168
  • Page 169 169
  • Page 170 170
  • Page 171 171
  • Page 172 172
  • Page 173 173
  • Page 174 174
  • Page 175 175
  • Page 176 176
  • Page 177 177
  • Page 178 178
  • Page 179 179
  • Page 180 180

Invacare Matrx PB Elite PBE Ohjekirja

Tyyppi
Ohjekirja
Tämä ohje sopii myös